Restricted airflow
Cause: The lint screen or the vent duct is blocked.
What to do: Clean the lint screen and check the vent hood outside. Have the duct cleaned if it is long.
Home / Appliances / Dryer
Gas and electric dryers: heating, drum, airflow and control repairs.
| Repair | Typical time | |
|---|---|---|
| Heating element replacementpopular | ~60 min · 3 mo warranty | |
| Gas igniter replacementpopular | ~50 min · 3 mo warranty | |
| Belt and roller replacement | ~70 min · 3 mo warranty | |
| Thermal fuse and thermostat replacement | ~40 min · 3 mo warranty | |
| Vent and lint path cleaning | ~45 min · 1 mo warranty | |
| Moisture sensor repair | ~45 min · 3 mo warranty |
Every visit starts with one flat service call. After the diagnosis you get an exact quote for parts and labor, and you decide before any work starts.
Troubleshooting
Error codes
Cause: The lint screen or the vent duct is blocked.
What to do: Clean the lint screen and check the vent hood outside. Have the duct cleaned if it is long.
Cause: The main electronic control has failed.
What to do: Unplug the dryer for 5 minutes. If the code returns, the board needs diagnostics.
Cause: The main electronic control has failed.
What to do: Unplug for 2 minutes. If it returns, the board needs diagnostics.
Cause: A button on the control panel is shorted or stuck.
What to do: Unplug for 2 minutes. If it returns, the user interface needs replacing.
Cause: The exhaust thermistor or its wiring is open.
What to do: The thermistor needs testing and replacing.
Cause: The heater circuit is open or one leg of power is missing.
What to do: Reset the breakers and clean the vent. If it returns, the heater circuit needs testing.
Cause: One leg of the 240 V supply is missing, usually a tripped breaker.
What to do: Reset both dryer breakers in the panel. If it returns, the outlet and cord need checking.
Cause: The supply voltage is out of range.
What to do: Have the outlet, breaker and cord checked.