Restricted airflow
Cause: The lint screen or the vent duct is blocked.
What to do: Clean the lint screen and check the vent hood outside. Have the duct cleaned if it is long.
Home / Dryer repair / Whirlpool / electric dryer
Whirlpool electric dryers, including the widely sold 29-inch drum design shared with Kenmore, Maytag and Roper. We repair them at your home across Charleston, North Charleston, Mount Pleasant, Summerville and the Lowcountry.
From our service calls
Blows when the vent is restricted and the dryer stops heating or starting.
The coil breaks and the drum turns but stays cold.
Thumping and squealing.
The motor runs but the drum stays still.
In Charleston
In humid Charleston summers a restricted vent shows up quickly as long drying times. Homes on the islands also need the outside vent flap checked for salt corrosion.
Owner tip: Clean the entire vent run once a year: almost every blown fuse on these dryers comes back to lint.
Repairs
On the display
Cause: The lint screen or the vent duct is blocked.
What to do: Clean the lint screen and check the vent hood outside. Have the duct cleaned if it is long.
Cause: The main electronic control has failed.
What to do: Unplug the dryer for 5 minutes. If the code returns, the board needs diagnostics.
Cause: The main electronic control has failed.
What to do: Unplug for 2 minutes. If it returns, the board needs diagnostics.
Cause: A button on the control panel is shorted or stuck.
What to do: Unplug for 2 minutes. If it returns, the user interface needs replacing.
Cause: The exhaust thermistor or its wiring is open.
What to do: The thermistor needs testing and replacing.
Cause: The heater circuit is open or one leg of power is missing.
What to do: Reset the breakers and clean the vent. If it returns, the heater circuit needs testing.
Cause: One leg of the 240 V supply is missing, usually a tripped breaker.
What to do: Reset both dryer breakers in the panel. If it returns, the outlet and cord need checking.