Home / Dryer repair / LG / electric and gas

LG electric and gas dryer repair

LG front-load dryers, matching the front-load washers. We repair them at your home across Charleston, North Charleston, Mount Pleasant, Summerville and the Lowcountry.

From our service calls

What fails on the electric and gas

  • Heating element or igniter

    No heat.

  • Thermal fuse

    Dryer will not start or heat.

  • Drum rollers

    Thumping or squeaking.

  • Flow sense alerts

    Restricted vent warnings.

In Charleston

In humid Charleston summers a restricted vent shows up quickly as long drying times. Homes on the islands also need the outside vent flap checked for salt corrosion.

Owner tip: Treat the flow sense warning as real: it means the vent is restricted.

Repairs

Common repairs for this dryer

On the display

LG dryer error codes

CL LG · Dryer

Child lock is on

Cause: Not a fault: the control panel is locked.

What to do: Hold the Child Lock button for 3 seconds.

You can check this yourself Book a repair
PF LG · Dryer

Power failure

Cause: Power was interrupted during the cycle.

What to do: Press Start to resume.

You can check this yourself Book a repair
PS LG · Dryer

Power cord wired incorrectly

Cause: The power cord is connected to the wrong terminals or the supply voltage is wrong.

What to do: An electrician or technician must check the cord and outlet.

Needs a technician Book a repair
d80 LG · Dryer

Exhaust is 80% blocked

Cause: The vent duct is clogged with lint or crushed behind the dryer.

What to do: Clean the lint filter and the full length of the vent duct to the outside.

You can check this yourself Book a repair
d90 LG · Dryer

Exhaust is 90% blocked

Cause: The vent duct is heavily clogged with lint or crushed.

What to do: Clean the full vent run to the outside before using the dryer again.

You can check this yourself Book a repair
d95 LG · Dryer

Exhaust is 95% blocked

Cause: The vent is almost completely blocked. This is a fire risk.

What to do: Stop using the dryer until the vent has been cleaned.

You can check this yourself Book a repair
nP LG · Dryer

No voltage

Cause: The dryer is not getting full power, usually a tripped breaker.

What to do: Reset both dryer breakers in the panel.

You can check this yourself Book a repair
tE1 LG · Dryer

Thermistor fault

Cause: The temperature sensor is open or shorted.

What to do: The thermistor needs replacing.

Needs a technician Book a repair

All LG dryer codes

Call Book a repair