Navien combi boiler repair

Navien combi boilers that provide heating and hot water. We repair them at your home across Charleston, North Charleston, Mount Pleasant, Summerville and the Lowcountry.

From our service calls

What fails on the combi boiler

  • Low water pressure

    Boiler locks out.

  • Ignition

    Will not fire.

  • Circulation pump

    Radiators stay cold.

  • Condensate

    Drain blockage codes.

In Charleston

Boilers are less common in the Lowcountry, but we service the hydronic and combi systems found in many older Charleston homes.

Owner tip: Check the pressure gauge regularly.

Repairs

Common repairs for this boiler

On the display

Navien boiler error codes

E003 Navien · Boiler

Ignition failure

Cause: No gas supply or a failed igniter.

What to do: Check the gas valve is open and press Reset. If it repeats, call a technician.

You can check this yourself Book a repair
E012 Navien · Boiler

Flame loss

Cause: The flame went out during operation.

What to do: Reset the boiler. If it continues, the flame rod and gas pressure need checking.

Needs a technician Book a repair
E016 Navien · Boiler

Overheating

Cause: Poor circulation or a blocked heat exchanger.

What to do: Turn the boiler off and let it cool. The pump and heat exchanger need checking.

Needs a technician Book a repair
E110 Navien · Boiler

Vent blockage

Cause: The air intake or exhaust is blocked.

What to do: Check the vent terminations outside for blockages.

You can check this yourself Book a repair
E302 Navien · Boiler

Low water pressure

Cause: System pressure has dropped — often a slow leak or a failed fill valve.

What to do: Check the pressure gauge. If it reads under 12 psi, the system needs refilling and leak-checking.

You can check this yourself Book a repair
E351 Navien · Boiler

Automatic fill fault

Cause: The make-up water valve could not bring the pressure up.

What to do: Check the water supply to the boiler is open. If it returns, call a technician.

You can check this yourself Book a repair
E352 Navien · Boiler

Water pressure too high

Cause: System pressure is over the limit: failed fill valve or expansion tank.

What to do: Do not keep resetting it. The expansion tank and fill valve need checking.

Needs a technician Book a repair